Measures
Ambient Air Temperature to Within 0.1° C.
APPLICATIONS
Automatic weather stations
Agricultural meteorological stations
Coastal monitoring stations
FEATURES
Well suited for remote monitoring
applications due to its high resistance
sensitivity
A network consisting of thermistor
and resistors composites
Solid state multi-element package
Produces a relatively large resistance
change per degree of temperature
Response time of 10 seconds in still
air
Linear analog DC voltage output proportional
to temperature that can be interfaced
directly to Sutron’s 8004 DCP,
8200A Data Recorder, and 8210 Data Recorder
SPECIFICATIONS subject to change without
notice
Range
-50°C
to +50°C
Accuracy
0.1°C
Input
Voltage
0-5
VDC
Maximum
Constant Network Voltage
3.5
VDC
Maximum
Constant Network Current
0.7
mA
Dimensions
3/8
in. diameter 4.25 in. length without
cable
Output
Range
0-3.5
VDC
ORDERING
5600-0020-2
Temperature Sensor, Air, linear with 15 ft. cable
Accessories
5600-0021-1
Radiation Shield, AT/RH, for sensors 0 to .5 inches diameter
Helpful
Hints
Radiation shield should be used when
monitoring ambient air temperature to prevent
solar radiation from inducing errors in
the reading.
Sutron
Corporation
22400 Davis Drive
Sterling,
VA 20164
(703)406-2800
(703)406-2801 fax sales@sutron.com