| Products » Dataloggers/Controllers » XPERT
DATALOGGER/CONTROLLER |
 |
XPERT DATALOGGER/CONTROLLER
8080-0000 |
SUTRON'S MOST POWERFUL DATALOGGER YET
|

The Xpert Datalogger/Controller, a high performance data recorder and communications device for UNATTENDED, REMOTE, REAL-TIME DATA ACQUISITION, CONTROL AND COMMUNICATIONS, is a multi-tasking logger capable of making measurements & communicating SIMULTANEOUSLY. Shown Above is Xpert Model 8080-0000-2B

Standard End Plate for all models Xpert
FEATURES
- 32MB FLASH MEMORY Standard for Log and Config Files Expandable via SD Cards
- Removable Media Support: SD Cards, MMC Cards, USB Thumb Drives
- Expandable I/Os
- UNPARALLELED SENSOR SUPPORT
The Xpert provides unparalleled sensor support through expansive I/O capabilities and built-in program libraries. The Xpert supports an array of measurement types:
Single Voltage |
Differential Voltage |
Resistance |
Frequency |
4-20mA |
| Counter |
Grey Code Binary |
Binary Alarm |
Binary |
Smart Serial |
| SDI-12 v1.3 |
RS-232 & RS-485 |
many more... |
|
|
Many sensors are supported specifically by name using one of the Xpert’s sensor “blocks” from its extensive built-in library. Support for any sensor can be added easily by writing a simple program in Xpert Basic. More complex custom processing tasks can be added by writing a program in C++ (required development tools are available for free from Microsoft).
- 4 COMMUNICATIONS SERIAL PORTS for SATELLITE TRANSMITTERS, MODEMS, RADIOS & OTHER SERIAL COMMUNICATION DEVICES.
- MULTIPLE TELEMETRY Options
• Satellite: GOES, INMARSAT, METEOSAT, INSAT, more!
• Voice/Data Modem (Cell, CDPD, Land Line Telephone...)
• LOS RADIO (UHF/VHF, Spread Spectrum...)
• MODBUS
• IRIDIUM
- VIEW DATA, CALIBRATE & ADJUST the Xpert using its LARGE TOUCH SCREEN. Locally or remotely, all Xpert FUNCTIONALITY IS ACCESSED THROUGH COMMUNICATIONS PORTS using easy to-understand set-up, data display & system maintenance GUIs (Accessible remotely via PDA & PC).
- ROBUST LOGGING & FLEXIBLE MEASURING & TRANSMISSION SCHEDULING
Logged data storage expandable with SD Cards. Changes to setup do not affect logged data. Logged data is compressed. System events are logged independently of measurement data.
- Flexible Scheduling
Each measurement can be independently scheduled. Sample intervals can be increments of 1 second to 24 hours, in 1 second increments. Built-in functions to support min, max, average, and accumulation calculations are provided. Changes to the setup do not affect logged data.
- Wide Operating Temperature (-40 to +60°C)
- Built-In Ethernet
- Event Driven Processing
Digital inputs can be configured to trigger measurement processing, including logging and telemetry transactions.
- Robust Display
The Xpert provides a backlit 1/4 VGA LCD touchscreen display. The display operates from -20 to +60°C. The transflective design of the display enables complete readability in full sunlight.
- Intuitive Interface
System setup and configuration is performed using the graphical user interface (GUI), either on the LCD touchscreen display, or remotely using XTerm. The interface is based on Microsoft Windows CE, and so should feel familiar and easy to use.
- Battery Operated, Low Power (2.5mA quiescent)
- Secure Access (user names & passwords
|
|
 |
Sutron’s XTerm
Software, provided with every Xpert,
allows the user to remotely program and
monitor the logger/controller in order
to see the same real-time data whether
in his office, on a service call, or
1000 miles away from the station or main
office.
|
 |
 |
SPECIFICATIONS |
| Dimensions |
8
1/2” x 6 1/2” x 2 1/2” |
| Weight |
2
lbs. |
| Temperatures |
-40°C
to +60°C Operating (Display -20°C
to +60°C) |
| Power Supply |
10-16 VDC recommended |
| Power Consumption |
Quiescent: 2.5 mA
Typical Avg: 5 mA @ 15 min sample intervals |
| Flash Memory |
32 MB Flash Memory for log & configuration files, expandable using SD Cards |
| Battery
Backup |
Internal lithium backup battery (for clock, not required for logged data)
2 years min |
| TCXO Real-Time Clock |
Real-time clock accuracy better than 10 seconds per month (-40°C
to +60°C) |
| Display |
1/4 VGA |
| Serial Ports |
4 RS-232 ports standard, up to 8 total
RS-485 options available
Dedicated SDI-12 bus
|
| Communications Types |
Satellite Radio, LOS Radio, Voice Modem (Speech Synthesis), Data Modem, Iridium, MODBUS, Direct Connect |
| Analog Inputs |
Every 8080-0003 Analog Module adds up to 6 additional analog inputs, so use as many modules as needed.
Every 8080-0007 Analog Module adds up to 10 additional analog inputs as needed.
|
| Digital I/O |
Every 8080-0002 Digital Module adds up to 8 additional digital I/O lines. Use as many modules as needed. |
| Removable Media |
SD Cards, MMC Cards, USB thumb drives |
| Ethernet |
802.3 10BaseT |
|
| |
ORDERING
XPERT DATALOGGER/CONTROLLER (including XTerm
Software) |
8080-0000-1B
|
Xpert with Display |
| 8080-0000-2B |
Xpert with Display
Includes
4 Additional Com Ports (Total of 8 Com Ports) |
| 8080-0001-1B |
Xpert without Display |
| 8080-0001-2B |
Xpert without Display
Includes 4 Additional Com Ports (Total of 8 Com Ports) |
| ORDERING XPERT I/O MODULES |
| 8080-0002-1 |
Xpert Digital I/O Module |
| 8080-0002-4 |
Xpert Digital I/O Module with Termination Board |
| 8080-0003-1 |
Xpert Analog I/O Module
6 Channels |
| 8080-0003-3 |
Xpert Analog I/O Module
6 Channels with Termination Board |
| 8080-0007-1 |
Xpert Analog I/O Module
10 Channels |
| 8080-0005-1 |
Voice Modem Module |
|
| |
CUSTOMIZED APPLICATIONS
EASILY CUSTOMIZE the Xpert with BASIC or C++ routines to be the core of virtually any hydrological, meteorological &/or control application including
- Automatic Weather Stations
- Agricultural/AgMet Stations
- Synoptic Weather Stations
- AWOS Stations
- Tidal Stations
- Hydro-Met Stations
- Water Level & Water Quality Stations
- Rainfall Stations
- Gate Control Stations
- Irrigation & Water Distribution Control Stations
- Stream Gaging Stations
- Dam Safety Stations
- Flood Forecasting, Monitoring, Control & Warning System
|
|
|
|