SDR SPECIFICATIONS |
Stage range |
+/- 80 ft of the set value |
Encoder |
400 count / revolution optical encoder 5.5 revolution / second MAX |
Clock |
Internal real-time clock with battery backup (coin cell with 5+ year life). ±2 minutes a month (0 to +50C). |
Recording intervals |
15-minute default, 1, 5, & 10 minutes user selectable. 30 & 60 minute intervals also available. |
Discharge calculation |
Parshall Flume & Broad Crested Weir Equations plus general purpose equation with user-selectable constants |
Volume total |
Daily volume calculation and logging |
Daily average stage & Volume |
Computes and logs the average daily stage and volume every day at midnight |
Operator interface |
6-button front panel with two-line display and status lights. Buttons select menu options. |
Available data |
Station name, date/time, current stage, current discharge, current total, battery voltage & logged values of the stage & discharge, daily average stage, average discharge & total discharge. |
Calibration |
The user can use the front panel/PC/PDA to adjust the current stage to match a staff reading (optional password protection) |
Setup data |
All setup stored in non-volatile flash memory |
Password |
Can be configured to require a password for setup changes and stage adjustments |
Log capacity |
Over one (1) year of 15-minute stage data with accompanying daily average of discharge and midnight battery voltage |
Log wrapping |
PERMANENT LOG wraps when full (oldest data replaced by newest data). There is NO mechanism to erase the log. |
Data downloads |
Compatible with Pocket PC , PDA or laptop/desktop Windows PC |
Event log |
Any stage or setup changes are written to the event log. |
Download time |
Less than 6 minutes, even for a 6-month log |
Download |
Comma-separated variable (CSV) |
Graphing data |
PDA and laptop utilities provide data graphing |
Status lights |
2 on front panel show “heartbeat” & run/error status |
Drive shaft |
5/16” diameter with 1: threaded & milled flat for set screw, shaft is 2.5” above base. |
Sealing |
NEMA rated enclosure resists dripping water & spray |
| MODBUS |
Supports MODBUS slave protocol with user-set address & baud rate |
| Float Wheels |
Can operate with the following diameters: 18 inch, 375 mm, 1 foot. |
| Operating Temperature |
-40°C to +60°C . The LCD operates to -10°C. |
| Data Connection |
DB9 (female) for direct connection to PC/PDA The DB9 provides +5V on pin 9 with a capacity of 71ma. Provides a means to power external devices, such as BlueTooth. |
| Grounding |
#8 ground stud with wing nut |
| SDI-12 |
One set of connections for SDI-12 on a terminal strip (Act as sensor or use to measure SDI-12 level of sensor.) |
| Battery Connection |
Dual battery connections on a terminal strip and appropriate circuitry to allow a new battery to be installed before the old battery is removed |
| Battery Life |
Operates on 5.5 to 16 vdc
3 to 9 months on standard gel cells (7 ah to 24 ah)
9 to 15 months on various series configurations of alkaline cells |
| Battery Voltage Log |
Battery voltage logged ech day at midnight, battery life indicator available in display |
| Power Consumption |
< 2.5 mA @ 12 VDC |
| Clock Backup |
A coin cell backs up the internal real-time clock. Battery life is 5+ years. |