•A FIRST CLASS RADIOMETER THAT PRECISELY MEASURES SUN & SKY RADIATION
•The 5600-0602 is a First Class Radiometer (as defined by the World Meteorological Organization, WMO); compliant with all ISO 9060 performance criteria.
FEATURES
The sensor can be used to measure total solar radiation or in defined wavelength bands. It features
Circular multi-junction Eppley wire-wound thermopile capable of withstanding severe mechanical vibration and shock
Receiver coated with Parson’s black lacquer (non-wavelengthselective
absorption)
Pair of removable precision ground and polished hemispheres of Schott optical glass
Both inner and outer hemispheres of clear WG295 glass, uniformly transparent to energy between about 285 and 2800 millimicrons
Includes a spirit level, adjustable leveling screws, and a desiccator which can be readily inspected
Cast bronze body with a white enameled guard disc
Schott optical glass for the outer hemisphere also
available in GG395 (clear), GG495 (yellow), OG530
(orange), RG630 (red), and RG695 (dark red)
Other Schott glasses and Infrasil II quartz hemispheres
available
Calibration certificate traceable to the World Radiation Reference included with conversion factors for various energy units
SPECIFICATIONS Subject to change without
notice
SPECTRAL RANGE
285 TO 2800 millimicron (nm)
SENSITIVITY
9μV/W/m2 (approx.)
IMPEDANCE
650 ohms (approx.)
TEMPERATURE DEPENDENCE
± 1% from -20°C to +40°C
LINEARITY
± 0.5% from 0 to 2800 W/m2
RESPONSE TIME
1 second (1/e signal)
COSINE
± 1% from 0 to 70° zenith angle,
±3% 70° to 80° zenith angle
ORIENTATION/TILT
No effect on instrument performance
MECHANICAL
VIBRATION
Tested up to 20 g's (no damage)
DIMENSIONS
5.75 in. Dia x 3.75 in. H
WEIGHT
7 LBS
CALIBRATION
Integrating hemisphere (approx. 1 cal. cm-2 min-1, ambient temperature +25°C)
ORDERING
5600-0602
Pyranometer, Precision Spectral WG295 glass standard (285 to 2800 nm) Specify outer Optional Schott colored glass outer hemisphere hemispheres:
GG395 (clear)
GG495 (yellow)
OG530 (orange)
RG630 (red)
RG695 (dark red)
ACCESSORIES
8111-1073-1 Amplifier with voltage and frequency outputs Note: For 8200 set J14 to
-DIFFIN and J15 to +DIFFIN. Wire to Analog 6 and 7. Configure sensor “pressure” for slope 1/sensitivty.