Economical & Reliable
for Routine Global Radiation Measurements
The 5600-0605 is a second class
pyranometer (as defined by the World
Meteorological Organization, WMO);
compliant with all ISO 9060 performance
criteria.
APPLICATIONS
Global radiation
Reflected solar radiation
Albedometer
FEATURES
Ruggedized, weather proof construction
Sealed and potted low maintenance
design
Excellent long term stability
of sensitivity
Good cosine/directional response
Built-in lifetime dessicant drying
cartridge!!!
Thermopile sensor (not silicon
cell)
Flat spectral sensitivity
Temperature compensation
Output is a millivolt signal.
Each sensor has its own calibration
certificate.
SPECIFICATIONS Subject to change without
notice
Spectral
Range
305
- 2800 nm (50% points)
Sensitivity
10
- 35µV/W/m2
Impedance
79
- 200 Ohms
Response
Time
95%
in 18 seconds
Non-linearity
<± 2.5%
(<1000 W/m2)
Operating
Temp
-40
to +80°C
Temperature
Dependence
± 6%
(-10 to +40°C)
Expected
Accuracy
± 10%
for daily sums
Tilt
Error
<± 2.5%
(<1000 W/m2)
Weight
343
grams
Maximum
Irradiance
2000
W/m2
DIrectional
Error
<± 25
W/m2 (Beam 1000 W/m2)
Cable
Length
5m
ORDERING
5600-0605
Pyranometer Second Class, 5m cable
Accessories
6661-1098-1
Mounting Kit, Pyranometer
(CAFI mounting bracket for Albedometer and CLFI leveling
fixture also available)