Captcha
View our Privacy Policy
Feedback





Captcha
View our Privacy Policy
Feedback

Total Precipitation Gauge (TPG)

Loading...

Total Precipitation Gauge (TPG)

    • Precision temperature compensated load cell.
    • Low power consumption
    • Featuring 0.001” measurement resolution.
    • Two built-in calibration routines for simple recalibration.
    • High accuracy: 0.02” -25C to +60C
    • Automatically saves data in permanent log
    • User-settable measurement, logging, and averaging (filtering)
    • Built-in flash log for 300,000 readings safeguards your data even if power is lost
    • Stand-alone operation or operation with other loggers/communications via SDI-12 and RS232
    • Front panel allows full access to setup, status and data
    • Provides redundant data storage when connected to a logger
    • Optional tipping bucket output
    • Optional heater
    • Optional autodrain mechanism
    •Hydro-Met monitoring systems
    •Municipal hydrology
    •Flood warning systems
    •Stormwater monitoring networks
    •Water balance models
    •Watershed and catchment basin studies
    •Climate change studies
    •Tropical and arctic monitoring
    •Tipping bucket upgrades
    •Replacement of Fischer/Porter gauges
    •CRN — Climate reference network
    •AWS – automatic weather stations
    •ASOS/AWOS – Automated Weather Observing System (airports)
    •NWS Co-op modernization

    • Measurements
    Precipitation, Precip rate, Internal Temp, Battery
    • Automeasure Interval
    1 second to 24 hours
    • Measurement Technique
    Precision hermetically sealed load cell
    • Accuracy
    0.02″ (0.6mm) -25C to +60C
    • Range
    36″ (914 mm) standard, >72″ (1800 mm) with optional drain kit
    • Autodrain Option
    Automataically drain into collection container when precip >75% capacity. System automatically tracks amount drained so that total precip can still be reported.
    • Heater Kit Option
    Heater kit provides rim heater and temperature sensor. The software only operates the heater when there is precipitation and the temperature is within user set limits.
    • Enclosure
    UV Resistant ABS plastic Cover, 8″ diameter aluminum inlet with knife edge. Cast aluminum base with 4″ pipe mount (for 4.5″ OD pipe)
    • Communication Ports
    SDI-12, RS232
    • Operating Temperature
    -40C to +60C
    • Display/Keypad
    no
    • Memory
     
                Built-In Flash >300,000 readings flash memory, >20 years data retention
                SD/MMC Card no
                 USB no
    • Ethernet
    no
    • Clock Accuracy (at 0C – 40°C)
    20 seconds per month (at 0°C– 40°C)
    • Power Requirements
    9-18 VDC
    Current Drain
    active
    • Communication Protocols Supported
    MODBUS, SDI-12
    • Programming
    via RS232, SDI-12
    • Device Dimensions
     
                       Height 28″ (71.2 cm)
                       Diameter 18″ (45.8 cm)
                       Weight 42 lbs. (19.1 kg)
                        Notes Options for autodrain and heater