Captcha
View our Privacy Policy
Feedback





Captcha
View our Privacy Policy
Feedback

IridiumLink 2-Way Logging Transmitter

Loading...

IridiumLink 2-Way Logging Transmitter

    1. GUI setup program. 2. Terminal strip with screw terminals for I/O and power connections 3. Operates 8-16VDC — 12V recommended for SDI-12 sensors 4. TCXO real-time clock with battery backup (+/-4ppm) 5. Solar panel regulator for panels up to 30 watts. 6. Support for up to 16 measurements of the following inputs:

    • SDI-12/RS485 (shared as is done in the Sutron Bubbler)
    • 5 Analog inputs:
      •  Two (2) single ended inputs (range 0-5V)
      •  Two (2) differential inputs (range +/-39mv, +/-312mV, +/-2.5V)
      •  One (1) 4-20mA input
    •  2 digital inputs. They can be used for tipping bucket, frequency, and on/off inputs
    •  2 internal SPI for future expansion
    •  Internal temperature
    •  Battery voltage
    •  Meta measurement

    7. Options to average or accumulate 8. Lightning protection (Gas Tube) on all external inputs. 9. User specified equation on any measurement . 10. User specified alarm detection on any measurement. 11. 2 LED for verification/diagnostics. 12. Log capacity of 240K of data accessible via Iridium® and direct connect 13. Switched Battery Output 14. Also operates as a standalone recorder without telemetry 15. USB slave for connection to PC. THE USB PORT WILL NOT WORK with USB devices like memory sticks, modems, etc. 16. Real Time Clock operates with internal lifetime battery.

    • Surface waterlevel,flow and quality
    • Groundwaterlevel and quality
    • Offshore X‐Linking
    • Mining / geotechnical
    • Weather X‐Linking and warning
    • Oceanic X‐Linking and warning
    • Oil and gas production
    • Any low‐power,remote data acquisition system

    Datasheets

    File Name Revision Number Release Date File Size Description
    IridiumLink Datasheet
    Jun 21, 2017 3.96MB
     
    X-Link with Display (6661-1324-1) Datasheet
    1.0 Apr 28, 2015 175.63KB
    X-Link Display is an accessory 

    Manuals

    File Name Revision Number Release Date File Size Description
    XLink O&M Manual
    1.63 May 24, 2016 5.02MB
    Fixed pseudobinary B alignment 
    LinkComm Quickstart Guide
    3.2.8 Jun 20, 2016 1.15MB
    Quick start guide updated to s 

    Presentations

    File Name Revision Number Release Date File Size Description
    IridiumLink Product Presentation
    Jul 24, 2014 21.53MB
    Product Presentation for Iridi 

    Software/Firmware

    File Name Revision Number Release Date File Size Description
    LinkComm for Mac OS X
    3.2.33 Aug 4, 2017 35.51MB
    Change History:
    LinkComm for PC
    3.2.33 Aug 4, 2017 109.80MB
    Change History:

    Tender Specifications

    File Name Revision Number Release Date File Size Description
    IridiumLink 2-Way Tender Specifications
    Jan 16, 2015 16.60KB
     

    Wireless Cost Estimator

    File Name Revision Number Release Date File Size Description
    Wireless Cost Estimator
    Aug 5, 2014 122.50KB
     
    • SPECIFICATIONS

      Specifications subject to change without notice

      Measurement Interval 1 second to 24 hours
      Number of Measurements 16 supported
      ANALOG 2 Single ended, 2 Differential, 1 4-20ma
      Single-Ended Analog 0-5 V (with respect to ground)
      Number available 2
      Input Range 0 to 5V (with respect to ground)
      Resolution 0.298 μV
      Noise (p/p) @250C 12.0 μV (p/p)
      Accuracy @250C 0.003% (typ) Midscale 0.004% Max
      Input Impedence > 1 MegOhm @250C
      Differential Analog
      Number Available 2
      Range (SW selectable) ±39mV; Common Mode Voltage Range .3 to 3.9 Volts ±312mV; Common Mode Voltage Range .3 to 3.9 Volts ±2.5V ; Common Mode Voltage Range .1 to 4.9 Volt
      Resolution 4.657 nV @ ±39mv scale, 37.25 nV @ ±312mv scale, 298 nV @ ±2.5v scale.
      Noise (p/p) @250C 1.6 μV (p/p) ±39 mv / 312 mv scale 5.0 μV (p/p) ±2.5 v scale
      Accuracy @250C 0.004% max @±2.5v scale
      Input Impedance @250C >5 Meg Ohm 312mV FS Differential
      4-20 mA Analog
      Range Resolution Accuracy @250C Loop Power Loop Resistance 0 – 22mA
      DIGITAL INPUTS/ OUTPUTS
      Digital Input 1, 2 Tipping Bucket Type Switch Contact Type. Pulse Width: 30ms – 120ms. Range: DC to 120 tips/min. (min).
      Digital Input 1,2 Frequency Type
      Minimum Frequency Maximum Frequency Input Range 2.8 Hz 10 KHz 0 – 5 V
      Digital Input 1,2 Counter Type
      Maximum Frequency 10 kHz (with no debouncing) 300 Hz (with debouncing)
      Input Range 0- 5 Volts
      INTERNAL TEMPERATURE
      Range -40 to +60°C
      Accuracy ±3 degrees
      ELECTRICAL
      Input Voltage 8-16VDC 10V min for SDI-12 sensor support Reverse power protected
      Current Consumption 0.5mA standby typ (all sensors unpowered) 8 to 20mA active typ
      Iridium Transmission 1 A @ 12 Volts
      Power Connection 2 position terminal strip
      SDI-12 Port 3 position terminal strip
      Red Warning LED Indicates setup or operation error
      Green Heartbeat LED Indicates unit operating properly
      Earth GND .2” screw terminal
      ENVIRONMENTAL
      Temperature -40°C to +60°C
      Humidity 0-95% Non-condensing
      KEY FEATURES
      Clock Internal real-time clock w/battery backup.
      Accuracy ±9.3 s /month(Max) -40 to +60°C. (First Year)
      Accuracy ±2.4 min /year (Max) -40 to +60°C. (First Year)
      Accuracy ±4.5 min / 10 years (Max) -40 to +60°C. (10 Years)
      Log Capacity 240,000 readings, flash memory
      USB Port Connector Serial Communications / USB port
      Mini-B Male USB connector on logger to be connected to USB Type-A Male (Windows PC). LinkComm software included for USB port communications
      Internal Solar Panel Battery Charger 5 – 20W Panels. (Max 30 Watts) Automatic charge & float modes protect gel cell & acid batteries.
      Iridium modem SMA-F Output RF Jack Modem factory installed, internal with RF output jack for antenna.
      COMMUNICATIONS
      Interfaces
      1 USB Mini-B Male (5 pin) Connector Serial Communications – USB. Not full function USB port. Iridium Modem SDI-12. RS485 (future support)
      SDI-12 interface V1.3 compliant recorder
      Supports up to 16 SDI-12 sensors Automatically combines requests to the same device +12V @ 500mA

Featured Products