HSPALink 2-Way Logging Transmitter

    • Easy-to-use Software includes setup program.
    • Terminal strip with screw terminals for I/O and power connections
    • Operates 8-16VDC
    • TCXO real-time clock with battery backup, typical ±5.4 sec/mo
    • Built-in solar panel regulator
    • Support for up to 16 measurements of the following inputs:
      • SDI-12/RS485 (not simultaneously)
      • 5 Analog Inputs:
        • 2 single ended inputs (range 0-5V)
        • 2 differential inputs (range ±39mv, ±312mV, ±2.5V)
        • 1 4-20mA input
      • 2 Digital Inputs. Use for tipping bucket, frequency, & on/off
      • Internal temperature
      • Battery voltage
    • Options to average or accumulate 1-8 measurements.
    • Lightning protection (Gas Tube) on all external inputs.
    • User specified equation on any measurement .
    • User specified alarm detection on any measurement.
    • 2 LED for verification/diagnostics.
    • Log capacity: 240K of data accessible via HSPA & direct connect
    • Switched Battery Output
    • Also operates as a standalone recorder without telemetry
    • USB slave for serial connection to PC (USB port does not support typical USB devices like memory sticks, modems, etc.)
    • RealTime Clock operates with internal lifetime battery.
    • 1 Open collector digital output
    • Switched 12 volt output

    Advanced Features

    • Equation processing & multiple level averaging
    • GUI Interface for intuitive programming (See LinkComm)
    • Command-line interface for operation without custom programs
    • Separate schedules for each measurement
    • Upgrade firmware via USB.
    • Supports SDI-12, Analog, 4-20ma input
    • Switched Power Output w/overload protection & Digital Output
    • Gas Tube Protection on Inputs
    • Max min or average computations on measurements
    • LED operational status feedback
    • WiFi access point (IEEE 802.11 b/g) with selectable Auto-Time-Out or Always-On modes

    HSPA Telemetry Benefits

    • Periodic transmissions at user-set times with data in user-selectable format (pseudobinary B, C, SHEF & ASCII)
    • Supports primary/secondary stations via HSPA
    • Alarm transmissions as they are detected
    • Diagnostics track data amount sent & telemetry performance
    • Supports up to 2 outputs (1 digital & 1 switched battery) for remote commands
    • Optional message authentication for insuring a trusted source & for messages sent to SutronWIN via HSPA
    • Incoming SMS transmissions if HSPA fails or in place of HSPA
    • Extremely affordable
    • HSPA uses 3.5G cellular technology to provide higher data speeds compared to GPRS
    • Surface Water Level, Flow & Quality
    • Groundwater Level & Quality
    • Offshore X-Linking
    • Mining / Geotechnical
    • Weather X-Linking & Warning
    • Oceanic X-Linking & Warning
    • Oil & Gas Production
    • Any Low-Power, Remote Data Acquisition System

    Datasheets

    File Name Revision Number Release Date File Size Description
    HSPALink Datasheet
    Apr 2, 2015 413.77KB
     
    X-Link with Display (6661-1324-1) Datasheet
    1.0 Apr 28, 2015 175.63KB
    X-Link Display is an accessory 

    Manuals

    File Name Revision Number Release Date File Size Description
    XLink O&M Manual
    1.63 May 24, 2016 5.02MB
    Fixed pseudobinary B alignment 
    LinkComm Quickstart Guide
    3.2.8 Jun 20, 2016 1.15MB
    Quick start guide updated to s 

    Software/Firmware

    File Name Revision Number Release Date File Size Description
    LinkComm for Mac OS X
    3.2.33 Aug 4, 2017 35.51MB
    Change History:
    LinkComm for PC
    3.2.33 Aug 4, 2017 109.80MB
    Change History:
      • Measurement Interval
      1 second to 24 hours
      • Number of Measurements Supported
      16
      • ANALOG Channels
      5 total, 2 Single ended, 2 Differential, 1 4-20ma
      • Single-Ended Analog
      0-5 V (with respect to ground)
                Number Available 2
                Input Range 0 to 5V (with respect to ground)
                Resolution 0.298 µV
                Noise (p/p) @25C 12.0 µV (p/p)
                Accuracy @25C 0.003% (typ) Midscale 0.004% Max
                Input Impedence > 1 MegOhm @25C
      • Differential Analog
       
                Number Available 2
                Range (SW selectable) ±39mV; Common Mode Voltage Range .3 to 3.9 Volts ±‐312mV; Common Mode Voltage Range .3 to 3.9 Volts ± 2.5V ; Common Mode Voltage Range .1 to 4.9 Volt
                Resolution 4.657 nV @ ±39mv scale, 37.25 nV @ ±312mv scale, 298 nV @ ±2.5v scale.
                Noise (p/p) @25C 1.6 µV (p/p) ±39 mv / 312 mv scale 5.0 µV (p/p) ±2.5 v scale
                Accuracy @25C 0.004% max @±2.5v scale
                Input Impedance @25C >5 Meg Ohm 312mV FS Differential
      • 4-20 mA Analog
       
                 Range 0-22 mA
                 Resolution <1nA
                 Accuracy @25C 0.02%
                 Loop Power External
                 Loop Resistance 200 Ohm
      • DIGITAL INPUTS/ OUTPUTS
       
      • Digital Input 1, 2 Tipping Bucket Type
      Switch Contact Type. Pulse Width: 30ms – 120ms. Range: DC to 120 tips/min. (min).
      • Digital Input 1,2 Frequency Type
       
                Minimum Frequency 2.8 Hz
                Maximum Frequency 10 KHz
                Input Range 0-5 V
      • Digital Input 1,2 Counter Type
       
                Maximum Frequency 10 kHz (with no debouncing) 300 Hz (with debouncing)
                Input Range 0- 5 Volts
      • INTERNAL TEMPERATURE
       
                Range  -40 to +60°C
                Accuracy ±3 degrees
      • ELECTRICAL
       
                Input Voltage 8-16VDC 10 V minimum for SDI-12 sensor support. Reverse power protected.
                Current Consumption 0.5mA standby typ (all sensors unpowered) 8 to 20mA active typ
                HSPA Transmission  
                Power Connection 2 position terminal strip
                SDI-12 Port 3 position terminal strip
                Red Warning LED Indicates setup or operation error
                Green Heartbeat LED Indicates unit operating properly
                Earth GND .2” screw terminal
      • ENVIRONMENTAL
                Temperature -40°C to +60°C
                Humidity 0-95% Non-condensing
      • KEY FEATURES
       
      • Clock
      Internal real-time clock w/battery backup.
                 Accuracy ±9.3 s /month(Max) -40 to +60°C. (First Year)
                 Accuracy ±2.4 min /year (Max) -40 to +60°C. (First Year)
                 Accuracy ±4.5 min / 10 years (Max) -40 to +60°C. (10 Years)
      • Log Capacity
      240,000 readings, flash memory
      • USB Port Connector
      Serial Communications / USB port
        Mini-B Male USB connector on logger to be connected to USB Type-A Male (Windows PC). LinkComm software included for USB port communications
      • Internal Solar Panel Battery Charger
      5 – 20W Panels. (Max 30 Watts) Automatic charge & float modes protect gel cell & acid batteries.
      • HSPA modem Quad Band HSPA Modem SMA-F Output RF Jack
      Modem factory installed, internal with RF output jack for antenna.
      • COMMUNICATIONS
       
                Interfaces 1 USB Mini-B Male (5 pin) Connector Serial Communications – USB. Not full function USB port. HSPA Modem. SDI-12. RS485 (future support)
                SDI-12 interface V1.3 compliant recorder
        Supports up to 16 SDI-12 sensors Automatically combines requests to the same device +12V @ 500mA
      • DIMENSIONS
      Operating
                Height 5.3″ (13.5 cm)
                Length 3.8″ (9.7 cm)
                Width 1.3″ (3.4 cm)
                Weight 1 lbs. (.46 kg)
      • DIMENSIONS
      Shipping
                Height 14 in. (35.6 cm.)
                Length 10 in. (25.4 cm.)
                Width 6 in. (15.3 cm.)
                Weight 2 lbs. (0.9 Kg)
      • Notes
      * Please refer to the X-Link User Manual for full product specifications and variations