Aquatrak Absolute Liquid Level Sensor & Controller

    • Tide and Sea Stage
    • River Stage
    • Groundwater
    • Piezometer
    • Head/Tail Water
    • Tank Ullage

    MEASUREMENT
    • Dynamic Range
    • Standard
    >35 feet (10 meters)
    • Optional
    >50 feet (15 meters)
    • Special
    75 feet (23 meters)
    • Rate of Change
    ± 10 feet (± 3 m/sec.)
    • Units
    English (Metric)
    • Resolution
    0.001 feet (1 mm)
    • Rate Proportionate
    1.2 – 2.4 per sec.
    • Rate Averaged 2 to 255
    1.0 per second
    • Interval
    Host Determined
    ACCURACY
    • Calibration
    • Standard
    ± 0.025%
    • Optional
    ± 0.01%
    • Non-linearity
    ± 0.02%
    • Precision, Repeatability
    ± 0.01 %
    • Stability, Drift, 1 year
    0
    • Temperature Drift
    < 1 ppm/°C
    ELECTRICAL
    • Voltage DC
    12.5 ± 2 volts
    • Average Power
    < 40 mA
    • Quiescent Current
    < 1 mA
    • Operating Current
    20 mW (4 sample average)
    ASCII SERIAL COMMUNICATION
    • EIA-485
    Consult Factory
    • RS-232
    N-8-1
    • SDI-12
    E-7-1
    • Selectable Baud Rate
    300 to 9600
    ENVIRONMENTAL
    • Operating Temperature
    -40 to 55 °C
    • Humidity
    -55 to 60 °C
    • Storage Temperature
    0 to 100%
    PHYSICAL
    • Controller 4100
    9 x 3.25 x 2.5 (inch)
    • Size
    (23 x 9 x 6 cm)
    • Weight
    2.5 lbs. (1.14 kg.)
    Sensor
    • Size
    4 inch dia. 8 inch ht. (9 cm dia. 21 cm ht.)
    • Shipping (1 carton)
    2.5 lbs. (1.14 kg.)
    • Weight
    5 lbs. (2.23 kg.)